Amperage Calculator

LITHIUM BATTERY CALCULATORS · AMPERAGE

Amperage Calculator

Amperage decides whether your wire is thick enough, your fuse is the right size and your battery’s BMS will stay connected. Watts tell you how much work a load does; amps tell you how much current has to flow to do it — and the same watts mean very different amps at different voltages. A 100W load draws 8.3A from a 12V battery, 0.83A from a 120V household circuit and 0.42A from a 240V circuit: same watts, ten times the current on the battery side. That is why a 12V system needs far heavier cable than a mains circuit for the same power, and why guessing the current is how wires overheat and BMS units trip.

This amperage calculator converts any load in watts to current in amps at your voltage — 12V, 24V or 48V for batteries, 120V or 240V for household mains. The formula is one line — amps = watts ÷ volts — but use the loaded voltage at the low end of the battery’s range, not the nominal voltage on the label, because a constant-power load draws more current as voltage falls. For AC loads there is one extra factor, power factor, explained in the formula table below. Check the tables before you buy cable, a fuse or a battery: if the current is above your BMS continuous rating, the system will shut down even though the battery still has energy left.

Worked examples (arithmetic verified in Python, 17 Nov 2026)

  1. 100W on a 12V battery: 100 ÷ 12 = 8.33A. On 120V mains it is 100 ÷ 120 = 0.83A; on 240V, 100 ÷ 240 = 0.42A.
  2. 1500W space heater on 120V: 1500 ÷ 120 = 12.5A — just under a standard 15A household circuit, which is why a 1500W heater plus anything else trips the breaker.
  3. 2400W on 240V: 2400 ÷ 240 = 10A. The same 2400W on a 12V battery would be 2400 ÷ 12 = 200A — no small battery cable can carry that, which is why high-power loads belong on 24V or 48V systems.
  4. How long will a 12V 100Ah battery run a 100W load? The load draws 8.33A, so 100Ah ÷ 8.33A = 12.0 hours at 100% depth of discharge. At 80% usable capacity it runs about 9.6 hours (80Ah ÷ 8.33A); voltage, temperature and BMS limits reduce real runtime further.
  5. AC load with power factor: a 1500W appliance on 120V AC with a typical power factor of 0.9 draws 1500 ÷ (120 × 0.9) = 13.89A, not 12.5A — power factor is why watts ÷ volts underestimates AC current for motors and some power supplies.
  6. Inverter load (battery side): a 700W AC load through an inverter at 90% efficiency needs 700 ÷ 0.90 = 777.8W from the battery — on 12V that is 777.8 ÷ 12 = 64.8A; on 24V, 32.4A; on 48V, 16.2A.

NEW — Table 1: common loads — watts at 12V / 120V / 240V → amps (ADD — this is the page’s core table)

Amps = watts ÷ volts. DC loads at 12V; household AC loads at 120V / 240V (before power factor — see Table 2). Wattages are typical values, not ratings for any specific model.

Load Watts 12 V (DC) 120 V (AC) 240 V (AC)
LED bulb 10 W 0.83 A 0.08 A 0.04 A
Phone / laptop charger 60 W 5.0 A 0.5 A 0.25 A
Small fan / 12V fridge (running) 100 W 8.3 A 0.83 A 0.42 A
TV 300 W 25.0 A 2.5 A 1.25 A
Microwave (small) 500 W 41.7 A 4.17 A 2.08 A
Kettle / heater (small) 1,000 W 83.3 A 8.33 A 4.17 A
Space heater 1,500 W 125.0 A 12.5 A 6.25 A
Air conditioner (small) 2,000 W 166.7 A 16.67 A 8.33 A
Water heater element 2,400 W 200.0 A 20.0 A 10.0 A
Electric cooker / large heater 3,000 W 250.0 A 25.0 A 12.5 A

Note under the table: “The 12V column is why high-power loads need higher system voltages — a 1,500W heater at 125A needs cable and a BMS that a 12V 100Ah battery cannot support, while the same load is only 12.5A on 120V mains. Size wire and fuses with headroom above the calculated current — do not run components at their absolute maximum rating.”

NEW — Table 2: amps formula variants (ADD)

What you know Formula Example
Watts and volts (DC) Amps = watts ÷ volts 100W ÷ 12V = 8.33A
Watts and volts (AC, single phase) Amps = watts ÷ (volts × power factor) 1500W ÷ (120V × 0.9) = 13.89A
Watts and volts (AC, three phase) Amps = watts ÷ (√3 × volts × power factor) 3000W ÷ (1.732 × 400V × 0.9) = 4.81A
Watt-hours and hours Amps = watt-hours ÷ (volts × hours) 1,280Wh ÷ (12.8V × 10h) = 10A
Amp-hours and hours Amps = amp-hours ÷ hours 100Ah ÷ 10h = 10A
Volts and resistance (Ohm’s law) Amps = volts ÷ ohms 12V ÷ 1.5Ω = 8A

Note under the table: “Power factor is 1.0 for resistive loads such as heaters, typically 0.8–0.95 for motors, compressors and many power supplies — 0.9 above is a typical household value, not a rating for any specific appliance. If the appliance label already states amps, use that figure instead of calculating.”

RELATED RESOURCES

Related Resources

These published resources answer the next question.

convert any load in watts to current in amps at your system voltageconvert amps back to wattsconvert watts to amps the other way roundhow long will this load run? Convert current back to runtimecheck whether the current is within your BMS continuous ratingall calculators

QUESTIONS & ANSWERS

Amperage Calculator: Frequently Asked Questions

Short answers to the questions visitors ask most.

How many amps does a 100W load draw?+

On a 12V battery, 100 ÷ 12 = 8.33A. On 120V mains, 0.83A. On 240V, 0.42A. Same watts — the current depends entirely on the voltage.

How do I calculate amps from watts and volts?+

Amps = watts ÷ volts. A 1500W heater on 120V draws 12.5A; a 2400W load on 240V draws 10A. For AC loads with motors or power supplies, divide by the power factor as well — amps = watts ÷ (volts × power factor), using 0.9 as a typical household value.

What is the difference between amps and watts?+

Watts measure power — how much work is done. Amps measure current — how much charge flows per second. Watts = volts × amps, so at a fixed voltage more watts always means more amps. Wire, fuses and BMS ratings are given in amps, not watts, which is why you convert before sizing anything.

How do I size a wire or breaker from amp draw?+

Calculate the maximum expected current first (use the lowest expected voltage, so the current is at its highest). Size the wire for that current, then choose overcurrent protection suitable for the wire — the fuse or breaker protects the wire, not just the load. Leave headroom for continuous loads and startup surges, which can be several times the running current. General guidance only — local electrical codes and the equipment datasheet decide the final sizes.

Can a 12V 100Ah battery supply 8.3 amps?+

Yes, easily — 8.33A is only 0.083C for a 100Ah battery, running about 12 hours at full discharge or 9.6 hours at 80% usable capacity. The question that matters is the other way round: a 100Ah battery with a 100A BMS limit cannot supply a 1,500W load on 12V, because that needs 125A. Check the battery’s continuous discharge current on its datasheet; the runtime calculator linked below converts any amp draw into hours.

Sources and Verification Status

Author: Saqib Jillani · Reviewer: lithiumbattery.info/ Editorial Team

  • Page-specific sources to cite: one 12V 100Ah LiFePO4 battery datasheet for the continuous discharge current and usable-capacity figures in FAQ 5; the appliance wattages in Table 1 are typical values, not ratings for any specific model — label them as such.