What this calculator does
This calculator estimates the usable energy of a LiFePO4 battery. Enter the number of series LiFePO4 cells, the cell or parallel-bank capacity in amp-hours, and the planned discharge fraction in percent. The workbench returns the usable energy in watt-hours.
Short answer: usable energy (Wh) = series cell count × 3.2 V × capacity (Ah) × discharge fraction (%) ÷ 100. At the workbench defaults — 4 series cells, 100 Ah, and 85% discharge — that is 4 × 3.2 × 100 × 0.85 = 1,088 Wh. The practical value of LiFePO4 Battery Calculator depends on the accuracy of those inputs.
Two things the workbench does not do. It has no efficiency input, so it does not subtract inverter or cable losses; and it does not output a runtime, a pack voltage, or a cell count. Runtime is a manual step — usable watt-hours divided by the load in watts — and pack voltage is a step in the middle of the calculation, shown in the worked example below. The old version of this page listed runtime, voltage and pack class as outputs; this version states the one output the workbench actually returns.
The formulas behind the result
Before relying on the result, identify V, A, Ah, W and Wh. A practical assessment of LiFePO4 Battery Calculator should retain the units and source of those observations.
Pack voltage (V) = series cell count × 3.2 V. LiFePO4 cells are rated at 3.2 V nominal, which is the basis for the common pack voltages: 4 cells in series give 12.8 V, 8 cells give 25.6 V, and 16 cells give 51.2 V. These are the packs sold as 12 V, 24 V and 48 V systems. Use the nominal figure, not the full-charge voltage: full charge is commonly around 3.65 V per cell, so a 4-cell pack reaches about 14.6 V when full, but its nominal energy is calculated at 12.8 V.
Nominal energy (Wh) = pack voltage (V) × capacity (Ah). A 12.8 V, 100 Ah LiFePO4 battery stores 12.8 × 100 = 1,280 Wh on paper. A 51.2 V, 100 Ah battery stores 5,120 Wh — four times the energy at the same amp-hours, because the voltage is four times higher. A cautious interpretation of LiFePO4 Battery Calculator includes the relevant operating limits.
Usable energy (Wh) = nominal energy (Wh) × discharge fraction (%) ÷ 100. At the defaults, 1,280 × 0.85 = 1,088 Wh. At 80% discharge the same battery gives 1,024 Wh. Runtime is then usable energy divided by the load: 1,024 Wh ÷ 300 W = 3.41 hours. Efficiency is a further manual step: at 98% system efficiency the usable energy at the load is 1,024 × 0.98 = 1,003.5 Wh, or 3.35 hours at 300 W.
Worked example: a 4-cell, 100 Ah LiFePO4 battery
Take the workbench defaults: 4 series LiFePO4 cells, 100 Ah of capacity, and an 85% planned discharge fraction. Each step below uses those figures, and the table replays them in order.
| Step | Calculation | Result |
|---|---|---|
| Pack voltage | 4 cells × 3.2 V | 12.8 V |
| Nominal energy | 12.8 V × 100 Ah | 1,280 Wh |
| Usable energy | 1,280 Wh × 0.85 | 1,088 Wh |
| Runtime at 300 W (manual) | 1,088 Wh ÷ 300 W | 3.63 hours |
| Runtime at 100 W (manual) | 1,088 Wh ÷ 100 W | 10.88 hours |
So the battery delivers 1,088 Wh of usable energy — about 3.63 hours at a steady 300 W load, or 10.88 hours at 100 W. At the more conservative 80% discharge fraction the same battery gives 1,024 Wh, or 3.41 hours at 300 W. The difference between the two discharge settings is 64 Wh, or about 13 minutes at 300 W. Record these assumptions whenever you use LiFePO4 Battery Calculator with another system.
The same arithmetic explains why LiFePO4 is planned around deep discharge. A lead-acid battery of the same nominal size is commonly planned around 50% usable capacity, so a 12.8 V, 100 Ah lead-acid bank would offer about 640 Wh usable against this battery's 1,088 Wh — the lithium bank delivers about 70% more usable energy from the same nominal size, before cycle life is even considered.
Usable energy for common LiFePO4 packs
The table below holds the discharge fraction fixed at 85%, exactly as the workbench computes it, and varies the series cell count and the capacity. Every row is the workbench formula applied to that pack.
| LiFePO4 pack | Pack voltage | Nominal energy | Usable energy at 85% |
|---|---|---|---|
| 4 cells, 100 Ah | 12.8 V | 1,280 Wh | 1,088 Wh |
| 4 cells, 200 Ah | 12.8 V | 2,560 Wh | 2,176 Wh |
| 8 cells, 100 Ah | 25.6 V | 2,560 Wh | 2,176 Wh |
| 8 cells, 200 Ah | 25.6 V | 5,120 Wh | 4,352 Wh |
| 16 cells, 100 Ah | 51.2 V | 5,120 Wh | 4,352 Wh |
| 16 cells, 200 Ah | 51.2 V | 10,240 Wh | 8,704 Wh |
Two patterns are worth noting. First, doubling the capacity doubles the energy, and doubling the series count does the same — energy is voltage times capacity, so an 8-cell, 100 Ah pack holds the same energy as a 4-cell, 200 Ah pack. Second, every figure above already includes the 15% reduction from the 85% discharge setting: a pack quoted at 10,240 Wh delivers 8,704 Wh to the load under that setting.
What each input means
Series LFP cell count is the number of LiFePO4 cells in series in the pack: 4 for a 12 V system, 8 for 24 V, 16 for 48 V. The workbench multiplies this count by the fixed nominal voltage of 3.2 V per cell, so the count sets the pack voltage. It must be a whole number — the workbench rejects a fractional cell count. This is the uncertainty that a LiFePO4 Battery Calculator worksheet should make visible.
Cell or parallel-bank capacity (Ah) is the amp-hour capacity of one cell, or of the parallel bank if cells are paralleled. Paralleled cells add amp-hours: two 100 Ah cells in parallel give 200 Ah at the same voltage. Enter the total amp-hours at the pack voltage, not the capacity of a single cell in a parallel group.
Planned discharge fraction (%) is the share of the battery you plan to use. Use 80% as a conservative LiFePO4 planning number unless the battery manufacturer clearly specifies a different routine operating window. LiFePO4 is commonly planned around 80% to 90% usable capacity; the exact limit for your battery is a datasheet figure, not a universal constant.
There is no efficiency input and no load input. The 3.2 V per cell is fixed by the workbench — it is the nominal voltage of a LiFePO4 cell, not a value you can change for another chemistry. For a different lithium chemistry, use the lithium battery calculator instead, and enter that chemistry's nominal voltage. A second LiFePO4 Battery Calculator scenario can reveal whether that difference matters.
Reading the result — and its limits
Treat the result as a planning estimate for a steady load. Runtime estimates assume an average steady load; real runtime changes with inverter losses, surge loads, low-temperature performance, BMS cutoffs, cable losses, and how conservative the system is about usable depth of discharge. A design that meets the daily energy total can still fail on a brief peak.
Temperature, age and measurement all move the answer. Cold reduces the energy a lithium battery delivers, and charging may be restricted at temperatures where discharging still works; an ageing pack holds less than its new-cell rating. Where the number matters — buying a battery, or sizing backup for an outage — run a low, central and high case by changing the discharge fraction by a plausible amount, and compare the result with a measured load rather than a guessed one.
The calculator cannot approve an installation. Charger profile, inverter voltage range, BMS current limits, cable size, fusing and ventilation must agree with each other and with the manufacturer's documentation. A correct arithmetic result on this page says nothing about whether the wiring is safe. In particular, a LiFePO4 charger must use the LiFePO4 voltage profile — a standard Li-ion charger should not be swapped in, because the full-charge voltages differ.
Sources and verification status
Author: Saqib Jillani · Reviewer: lithiumbattery.info Editorial Team Use LiFePO4 Battery Calculator to examine the numbers, not to override a manufacturer limit.
The formulas and worked numbers on this page are arithmetic from the inputs stated beside them — every figure can be reworked with a pocket calculator. The workbench defaults (4 cells, 100 Ah, 85%) give 1,088 Wh, which the workbench itself reproduces. The 3.2 V nominal per cell, the 3.65 V full-charge figure and the 2.5 V lower cutoff guidance are the standard LiFePO4 conventions used across this site's battery guides; a named cell datasheet citation is still to be added. The 2,000 to 5,000 cycle range and the 97% to 99% efficiency modelling figure are planning conventions carried over from the previous version of this page, not measurements. The 80% to 90% usable discharge planning range is a convention, not a datasheet value. For background on how batteries store energy, see the U.S. Department of Energy battery reference linked below.