What this calculator does
This calculator turns a battery's label figures into the two numbers that matter for planning: how much energy you can actually use, and how long it will run a load. Enter the nominal voltage, the rated capacity in amp-hours, the share of capacity you plan to use, and the delivery efficiency. The workbench returns the usable energy in watt-hours, with the nominal energy shown alongside it. A cautious interpretation of Lithium Battery Calculator includes the relevant operating limits.
Short answer: usable watt-hours = nominal volts × amp-hours × depth of discharge × efficiency. Divide usable watt-hours by the load in watts for runtime in hours. Reverse the steps to size a battery: required watt-hours = load watts × hours ÷ (depth of discharge × efficiency), then divide by voltage for amp-hours. The practical value of Lithium Battery Calculator depends on the accuracy of those inputs.
The split between nominal and usable energy is the whole point. A battery's label states what it stores under reference conditions, not what reaches your load after discharge limits and conversion losses. Planning from the label alone overstates runtime; planning from usable energy does not.
The formulas behind the result
Five formulas cover everything this page calculates. All five use nominal voltage — the battery's rated voltage, not its full-charge voltage — and all five are arithmetic on the numbers you enter, so you can check each one by hand.
Nominal energy (Wh) = nominal voltage (V) × capacity (Ah). A 12.8 V, 100 Ah battery stores 1,280 Wh on paper.
Usable energy (Wh) = nominal energy × depth of discharge × efficiency. The workbench defaults are 80% depth of discharge and 90% efficiency, so the same battery delivers 1,280 × 0.80 × 0.90 = 921.6 Wh in the default case.
Runtime (hours) = usable energy (Wh) ÷ load (W). At a steady 100 W load, 921.6 ÷ 100 = 9.2 hours.
Load current (A) = load power (W) ÷ battery voltage (V). A 500 W load on a 24 V battery draws 500 ÷ 24 = 20.8 A — the figure to check against cable, fuse and battery discharge limits. This is the uncertainty that a Lithium Battery Calculator worksheet should make visible.
Required capacity (Ah) = load (W) × hours ÷ (depth of discharge × efficiency) ÷ voltage (V). This is the sizing formula, worked in the example below. Record these assumptions whenever you use Lithium Battery Calculator with another system.
Worked example: a 100 W load on a 12.8 V, 100 Ah battery
Take a common case: a 12.8 V, 100 Ah LiFePO4 battery, the 12 V size sold for solar, RV and backup use, running a steady 100 W load such as a small fridge and lights together. The workbench defaults are 80% depth of discharge and 90% efficiency, and each step below uses those figures.
| Step | Calculation | Result |
|---|---|---|
| Nominal energy | 12.8 V × 100 Ah | 1,280 Wh |
| After 80% depth of discharge | 1,280 × 0.80 | 1,024 Wh |
| After 90% efficiency | 1,024 × 0.90 | 921.6 Wh |
| Runtime at 100 W | 921.6 ÷ 100 | 9.2 hours |
| Load current at 12.8 V | 100 ÷ 12.8 | 7.8 A |
So the battery runs the load for about 9.2 hours — not the 12.8 hours the label figures suggest (1,280 ÷ 100). The gap is the whole lesson: depth of discharge and efficiency together remove 28% of the label energy in the default case. Change either assumption in the workbench and the runtime moves with it.
Sizing runs the same steps backwards. A 200 W load that must run for 8 hours needs 200 × 8 = 1,600 Wh at the load. With the same 80% depth of discharge and 90% efficiency, the battery must store 1,600 ÷ (0.80 × 0.90) = 2,222 Wh — about 174 Ah at 12.8 V (2,222 ÷ 12.8 = 173.6). A single 12.8 V, 100 Ah battery (1,280 Wh) cannot do this job; a 200 Ah bank (2,560 Wh) can, with 1,843 Wh usable.
With deeper settings — 90% depth of discharge and 95% efficiency — the same battery gives 1,280 × 0.90 × 0.95 = 1,094 Wh, or 10.9 hours at 100 W. Use those figures only if your battery's datasheet supports 90% usable discharge and your system really delivers 95% efficiency. The defaults (80% and 90%) are the conservative starting point.
Common battery sizes at a glance
The table below applies the workbench defaults — 80% depth of discharge, 90% efficiency — to the battery sizes readers ask about most. Voltages are nominal pack voltages: 12.8 V, 25.6 V and 51.2 V are the 4-series, 8-series and 16-series LiFePO4 packs sold as 12 V, 24 V and 48 V systems.
| Battery | Nominal energy | Usable energy | Runtime at 100 W |
|---|---|---|---|
| 12.8 V, 50 Ah | 640 Wh | 461 Wh | 4.6 h |
| 12.8 V, 100 Ah | 1,280 Wh | 922 Wh | 9.2 h |
| 12.8 V, 200 Ah | 2,560 Wh | 1,843 Wh | 18.4 h |
| 25.6 V, 100 Ah | 2,560 Wh | 1,843 Wh | 18.4 h |
| 51.2 V, 100 Ah | 5,120 Wh | 3,686 Wh | 36.9 h |
Two patterns are worth noting. Doubling capacity doubles runtime, but doubling voltage at the same amp-hours does the same — energy is voltage times capacity, so a 25.6 V, 100 Ah battery holds the same energy as a 12.8 V, 200 Ah one. And every figure above already includes the 28% reduction from the default assumptions: a battery quoted at 5,120 Wh delivers 3,686 Wh to a 100 W load under those settings. Use Lithium Battery Calculator to examine the numbers, not to override a manufacturer limit.
What each input means
Nominal voltage is the battery's rated voltage, not the voltage when fully charged. A LiFePO4 cell is 3.2 V nominal, so a 4-cell series pack is 12.8 V; a Li-ion or LiPo cell is 3.6–3.7 V nominal, so the same series count gives a higher pack voltage. Enter the nominal figure from the battery label or datasheet — using full-charge voltage here inflates every result. A second Lithium Battery Calculator scenario can reveal whether that difference matters.
Capacity in amp-hours is the charge the battery is rated to deliver under the manufacturer's stated conditions, usually a stated discharge rate and temperature. Two batteries with the same amp-hours but different voltages store different energy, which is why this calculator works in watt-hours.
Depth of discharge is the share of the battery you plan to use. Lithium batteries are commonly planned around 80–90% usable capacity — deeper than lead-acid, which is commonly planned around 50%. The exact limit for your battery is a datasheet figure, not a universal constant; the workbench default is 80%.
Delivery efficiency combines the losses between the battery and the load: inverter conversion, cables and control electronics. The 90% default is a planning figure for a small inverter system. If you know a measured efficiency, use it; if your system has long cable runs or a large inverter idling, expect a lower figure. Do not also subtract the same loss in the depth-of-discharge figure — that double-counts it.
Reading the result — and its limits
Treat the result as a planning estimate for a steady load. Real loads vary: compressors cycle, motors draw a starting surge several times their running current, and inverters consume power even with no load. A design that meets the daily energy total can still fail on a brief peak, so check sustained current and short-duration limits against the battery and inverter datasheets separately.
Temperature, age and measurement all move the answer. Cold reduces the energy a lithium battery delivers, and charging may be restricted at temperatures where discharging still works; an ageing pack holds less than its new-cell rating. Where the number matters — buying a battery, or sizing backup for an outage — run a low, central and high case by changing the inputs a plausible amount, and compare the result with a measured load rather than a guessed one.
The calculator cannot approve an installation. Charger profile, inverter voltage range, BMS current limits, cable size, fusing and ventilation must agree with each other and with the manufacturer's documentation. A correct arithmetic result on this page says nothing about whether the wiring is safe. A follow-up using Lithium Battery Calculator should change only one input at a time.
Sources and verification status
Author: Saqib Jillani · Reviewer: lithiumbattery.info Editorial Team The result from Lithium Battery Calculator should be compared with the equipment specification.
The formulas and worked numbers on this page are arithmetic from the inputs stated beside them — every figure can be reworked with a pocket calculator. The nominal cell voltages (3.2 V LiFePO4; 3.6–3.7 V Li-ion and LiPo) are the standard conventions used across this site's battery guides; a named cell datasheet citation is still to be added. The 80% depth-of-discharge and 90% efficiency defaults are planning conventions, not measurements. For background on how batteries store energy, see the U.S. Department of Energy battery reference linked below.